Code #35: internal command, Code #36: not supported, Code #37: not supported – INFICON MDC-260 Thin Film Deposition Controller User Manual

Page 184: Code #38: remote activation of controller, Code #35: internal command -46, Code #36: not supported -46, Code #37: not supported -46, Code #38: remote activation of controller -46

Advertising
background image

MDC-260 DEPOSITION CONTROLLER

COMPUTER INTERFACE

11-46

Code #35: Internal Command

Description:

Instruction Code #32 is used by the software interface package and

is not designed for external interfacing.

Code #36: Not Supported

Description:

Instruction Code #36 is not supported by the MDC-260. Attempting

to issue it to the controller will result in an “Invalid Instruction Code” error in the
message receipt.

Code #37: Not Supported

Description:

Instruction Code #37 is not supported by the MDC-260. Attempting

to issue it to the controller will result in an “Invalid Instruction Code” error in the
message receipt.

Code #38: Remote Activation of Controller

Description:

This instruction initiates a remote action. The possible actions are

shown in the following table:

Remote Action Code

Description

Action Trigger Type

0

Sound Alarm Action

Momentary

1 Sound

Alert

Action

Momentary

2

Sound Attention Action

Momentary

3

Step From State Action

One Shot

6

Clear Hold in State Action

Continuous

5

Set Hold in State Action

Continuous

6

Terminate Deposit Action

One Shot

7

Halt Process Action

One Shot

8

Switch Crystals

One Shot


All the momentary actions trigger the action for a 100-millisecond period for each
message received. The one shot actions trigger the action once for each message
received. For example, sending one step from state message would cause the
controller to step into the next state one time. The continuous actions trigger that
action indefinitely. So the set hold in state action will cause the controller to hold
in the current state until the clear hold in state action is received and the exit state
condition is meet.


Format/Example:

• To initiate a Terminate Deposit action, transmit:

Header

Interface

Address

Inst.

Code

Length

Remote Action

Code

Checksum

Dec

255 254

1

38

1

6 210

Advertising