I/o status screen, Active layer parameter update screen, Position control screen – INFICON MDC-260 Thin Film Deposition Controller User Manual

Page 83: I/o status screen -5, Active layer parameter update screen -5, Position control screen -5, Figure 5-9 i/o status screen -5, Figure 5-11 position control screen -5

Advertising
background image

MDC-260 DEPOSITION CONTROLLER

OPERATING THE MDC-260

5-5

5.6.3 I/O

STATUS

SCREEN

Figure 5-9 I/O Status Screen

The I/O Status screen indicates the state of all the MDC-260's inputs and outputs.
Please note that you can use the arrow keys to scroll up and down the I/O listing.

5.6.4 ACTIVE LAYER PARAMETER UPDATE SCREEN

Figure 5-10 Active Layer Parameter Update Screen

The Active Layer Parameter Update screen displays a set of parameters of the
current active layer as shown in Figure 5-10. It allows the user to quickly change
these values, if needed, to fine-tune the run, without having to go into the Edit
Material Definition screen. To change a value, use the arrow keys to move the
cursor to highlight it, punch in the new value and press Enter. Note that values
changed in this screen will be written back to the material definition. Note that
this screen is only available during a process.

5.6.5 POSITION CONTROL SCREEN

Figure 5-11 Position Control Screen

Sample Cr Process Ready
Input State Output State

01 Source1 BCD 0 F Source1 BCD 0 F

02 Source1 BCD 1 T Source1 BCD 1 T
03 F Source1 Shutter F
04 F F
05 F F
06 F F

Sample Cr Predeposit Hold
Active Layer Parameter Update
Sensor

1

Soak Pwr

25.0

Crystal

01

Predep. Pwr 32.0

Thickness 1.500 Max Pwr

55.0

Rate #1

010.0 Prop. Gain

1000

Rate #2

000.0 Int. Time

99.9

Rate #3

000.0

Deriv. Time

00.0

Sample Cr Process Ready
Position Control

Command Actual Health

Source 1 Pocket: CM 01

N/A

Source 2 Pocket:

--

N/A

Sensor 1 Crystal:

--

99%

Sensor 2 Crystal:

--

00%

Advertising