Material parameters, Material parameters -4 – INFICON MDC-260 Thin Film Deposition Controller User Manual

Page 22

Advertising
background image

MDC-260 DEPOSITION CONTROLLER

GENERAL DESCRIPTION

1-4

1.3.6 MATERIAL

PARAMETERS

Material Name

10 character string

Sensor #

1 to 2

Crystal #

1 to 16

Source #

1 to 2

Pocket #

1 to 16

Density

0.80 to 99.9 gm/cm

3

Acoustic Impedance

0.50 to 59.9 gm/cm

2

sec

Tooling Factor

10.0 to 499.9%

Proportional Gain

0.00 to 9999

Integral Time Constant

0 to 99.9 sec

Derivative Time Constant

0 to 99.9 sec

Rise to Soak Time

0 to 9:59:59 H:MM:SS

Soak Power

0 to 99%

Soak Time

0 to 9:59:59

Rise to Predeposit Time

0 to 9:59:59

Predeposit Power

0 to 99.9%

Predeposit Time

0 to 9:59:59

Rate Establish Time

0 to 60 sec

Rate Establish Error *

0 to 99.9%

Deposition Rate (#1, #2*, #3*)

00.0 to 999.9 Å/sec

Ramp (#1, #2*) Start Thickness

0 to 100% [100% = Ramp Disabled]

Ramp (#1*, #2*) Stop Thickness

0 to 100%

Time Setpoint

0 to 9:59:59

Ramp to Feed Time

0 to 9:59:59

Feed Power

0 to 99.9%

Feed Time

0 to 9:59:59

Ramp to Idle Time

0 to 9:59:59

Idle Power

0 to 99.9%

Maximum Power

0 to 99.9%

Power Alarm Delay

0 to 99 sec

Minimum Power

0 to 99.9%

Rate Deviation Attention

0 to 99.9%

Rate Deviation Alarm

0 to 99.9%

Rate Deviation Abort

0 to 99.9%

Sample Dwell %

0 to 100%

Sample Period *

0:01:00 to 9:59:59

Crystal Fail

Switch, Time Power, Halt, Abort

Backup Sensor #

1 to 2

Backup Crystal #

1 to 16

Backup Tooling Factor

10.0 to 499.9%

Material Password

4 character string

* These options are made available based on the settings of surrounding

parameters, and will not appear if their value is not needed.