Code #02: send utility parameters, Code #02: send utility parameters -13 – INFICON MDC-260 Thin Film Deposition Controller User Manual

Page 151

Advertising
background image

MDC-260 DEPOSITION CONTROLLER

COMPUTER INTERFACE 11-13

Code #02: Send Utility Parameters

Description:

Instructs the controller to send the utility parameters to the host

computer. The following is a description of the data transmitted.

Prm#

Parameter Name

Length

(bytes)

Values

(decimal)

1

Pause on Layer Complete

1

4 = No, 5 = Yes

2

Negative Thickness Enable

1

6 = Enabled

, 7 = Disabled

3

Thickness Graph Scale

1

8 = 2 Digit, 9 = 3 Digit

4

Sensor Status Select

1

10 = Thickness

, 11 = Frequency

5




Time To Go Display

1




12 = Estimated Layer,
13 = Estimated State,
14 = Elapsed Process,
15 = Elapsed Layer,
16 = Elapsed State

6 Rate

Graph

1 6 = Enabled, 7 = Disabled

7 Power

Graph

1 6 = Enabled, 7 = Disabled

8 Thickness

Graph

1 6 = Enabled, 7 = Disabled

9

Rate Deviation Graph

1

6 = Enabled

, 7 = Disabled

10 Source/Sensor

Status

1 6 = Enabled, 7 = Disabled

11 I/O

Status

1 6 = Enabled, 7 = Disabled

12

Crystal Frequency

1

39 = 2.5 MHz, 40 = 3.0 MHz,
41 = 5.0 MHz, 42 = 6.0 MHz,
43 = 9.0 MHz, 44 = 10.0 MHz

13 Simulate

Mode

1 45 = Off, 46 = On

14

USB Interface Address

1

01

, 02, 03 ... 32

15 Attention

Volume

1 0,

1

, 2, 3 ... 10

16 Alert

Volume

1 0,

1

, 2, 3 ... 10

17 Alarm

Volume

1 0,

1

, 2, 3 ... 10

18

Starting Layer Number

1

0, 1, 2, 3 ... 10

Total: 18 Data Bytes


Format/Example:

• To instruct the controller to send the utility parameters, transmit:

Header

Interface

Address

Instruction

Code

Length Checksum

Dec

255 254

1

2 0

253

Hex

FF FE 01

02 00

FD