Function library, Function blocks, 17 signal conversion (conv) – Lenze EVS9332xS User Manual

Page 100: Conv3, Conv4, Conv5

Advertising
background image

Function library

Function blocks

3.2.17

Signal conversion (CONV)

3−48

l

EDSVS9332S−EXT EN 2.0

CONV3

CONV3

CONV3-OUT

CONV3-IN

C0953

C0952

C0950
C0951

Fig. 3−44

Function block CONV3

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

CONV3−IN

phd

C0953

dec [rpm]

C0952

4

1000

CONV3−OUT

a

Limited to ±199.99 %

This function block is used to convert speed signals into analog signals.

The conversion is done according to the formula:

CONV3−OUT

+ CONV3−IN @

100 %

15000 rpm

@ C0950

C0951

CONV4

CONV4

CONV4-OUT

CONV4-IN

C0958

C0957

C0955
C0956

Fig. 3−45

Function block CONV4

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

CONV4−IN

phd

C0958

dec [rpm]

C0957

4

1000

CONV4−OUT

a

Limited to ±199.99 %

This function block is used to convert speed signals into analog signals.

The conversion is done according to the formula:

CONV4−OUT

+ CONV4−IN @

100 %

15000 rpm

@ C0955

C0956

CONV5

CONV5

CONV5-OUT

CONV5-IN

C0658

C0657

C0655
C0656

Fig. 3−46

Function block CONV5

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

CONV5−IN

a

C0658

dec [%]

C0657

1

1000

CONV5−OUT

phd

Limited to ±29999 rpm

This function block is used to convert analog signals into speed signals.

Conversion according to formula:

CONV5−OUT

+ CONV5−IN @

15000 rpm

100 %

@ C0655

C0656

Advertising