Input value with sign reversal (phint3), Function library, Function blocks – Lenze EVS9332xS User Manual

Page 206

Advertising
background image

Function library

Function blocks

3.2.53

Phase integrator (PHINT)

3−154

l

EDSVS9332S−EXT EN 2.0

3.2.53.3

Input value with sign reversal (PHINT3)

C1150 = 2

The input PHINT3−LOAD is state−controlled (HIGH level).

l

PHINT3−LOAD = HIGH

– The integrator is loaded with the input value at PHINT3−SET.

– Sets the output PHINT3−STATUS = LOW.

P H I N T 3 - O U T

P H I N T 3 - S T A T U S

C 1 1 5 1

- C 1 1 5 1

C h a n g e o f s i g n a t t h e i n p u t

Fig. 3−143

Function of PHINT3 with sign reversal of the input value at C1150 = 2

l

The FB integrates speed or velocity values at PHINT3−IN to a phase (distance).

l

PHINT3−OUT outputs the count of the bipolar integrator.

– A positive value at PHINT3−IN increments the integrator (count is increased).

– A negative value at PHINT3−IN decrements the integrator (count is reduced).

l

If the counter content exceeds the value of (+) C1151

– the value of C1151 is subtracted from the counter content,

– switches PHINT3−STATUS = HIGH for 1 ms.

l

If the counter content falls below the value of () C1151

– the value of C1151 is added to the counter content,

– switches PHINT3−STATUS = HIGH for 1 ms.

Advertising