53 phase integrator (phint), Phase integrator (phint), Function library – Lenze EVS9332xS User Manual

Page 202: Function blocks

Advertising
background image

Function library

Function blocks

3.2.53

Phase integrator (PHINT)

3−150

l

EDSVS9332S−EXT EN 2.0

3.2.53

Phase integrator (PHINT)

Purpose

Integrates a speed or a velocity to a phase (distance). The integrator can maximally accept ±32000
encoder revolutions.

PHINT3 can recognise a relative distance.

C 0 9 9 2

P H I N T 1

P H I N T 1 - O U T

P H I N T 1 - I N

C 0 9 9 3

P H I N T 1 - R E S E T

C 0 9 9 0

C 0 9 9 1

± 3 2 0 0 0

R e v o l u t i o n

P H I N T 1 - F A I L

Fig. 3−138

Phase integrator (PHINT1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

PHINT1−IN

phd

C0992

dec [rpm]

C0990

4

1 revolution = 65536 increments

PHINT1−RESET

d

C0993

bin

C0091

2

HIGH = sets the phase integrator to 0 and PHINT1−FAIL
= LOW

PHINT1−OUT

ph

65536 inc = 1 encoder revolution, overflow is possible

PHINT1−FAIL

d

HIGH = overflow

C 1 0 3 2

P H I N T 2

P H I N T 2 - O U T

P H I N T 2 - I N

C 1 0 3 3

P H I N T 2 - R E S E T

C 1 0 3 0

C 1 0 3 1

± 3 2 0 0 0

R e v o l u t i o n

P H I N T 2 - F A I L

Fig. 3−139

Phase integrator (PHINT2)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

PHINT2−IN

phd

C1032

dec [rpm]

C1030

4

1 revolution = 65536 increments

PHINT2−RESET

d

C1033

bin

C1031

2

HIGH = sets the phase integrator to 0 and PHINT2−FAIL
= LOW

PHINT2−OUT

ph

65536 inc = 1 encoder revolution, overflow is possible

PHINT2−FAIL

d

HIGH = overflow

Advertising