Digital frequency ramp function generator (dfrfg), Function library, Function blocks – Lenze EVS9332xS User Manual

Page 121: Function, Profile generator, Quick stop, Ramp function generator stop, Reset, Detect phase difference, Start via touch probe initiator (terminal x5/e5)

Advertising
background image

Function library

Function blocks

3.2.26

Digital frequency ramp function generator (DFRFG)

3−69

l

EDSVS9332S−EXT EN 2.0

3.2.26

Digital frequency ramp function generator (DFRFG)

Purpose

The drive (motor shaft) is synchronised to a digital frequency (phase selection). The drive then
performs a phase−synchronous operation with the digital frequency.

FB_dfrfg1

C 0 7 5 1

D F R F G 1 - O U T

C 0 7 6 4 / 3

D F R F G 1 - R E S E T

D F R F G 1

C 0 4 2 9

C 0 7 6 4 / 2

C 0 7 6 4 / 1

C 0 7 6 0

C 0 7 5 9

D F R F G 1 - Q S P

D F R F G 1 - S T O P

C 0 7 6 1

C 0 7 6 5

C 0 7 5 8

D F R F G 1 - I N

C 0 7 5 2

C 0 7 5 4

S

R

Q

D F R F G 1 - F A I L

D F R F G 1 - S Y N C

C T R L

C 0 7 5 3

E 5

X 5

1

0

C 0 7 5 7

C 0 7 5 6

C 0 7 5 5

0

C 0 7 6 6

Fig. 3−65

Digital frequency ramp function generator (DFRFG1)

Signal

Source

Note

Designation

Type

DIS

DIS format

CFG

List

DFRFG1−SET

phd

C0769

C0768

Initial speed

DFRFG1−IN

phd

C0765

dec [rpm]

C0758

4

Speed/Phase setpoint

DFRFG1−QSP

d

C0764/1

bin

C0759

2

HIGH = quick stop

DFRFG1−STOP

d

C0764/2

bin

C0760

2

HIGH = save setpoint

DFRFG1−RESET

d

C0764/3

bin

C0761

2

HIGH = reset

DFRFG1−OUT

phd

Speed/Phase setpoint

DFRFG1−SYNC

d

HIGH = drive runs synchronously

DFRFG1−FAIL

d

HIGH = phase difference exceeded

Function

l

Profile generator

l

Quick stop

l

Ramp function generator stop

l

RESET

l

Detect phase difference

l

Start via touch probe initiator (terminal X5/E5)

l

Correction of the touch probe initiator (terminal X5/E5)