55 cw/ccw/qsp linking (r/l/q), Cw/ccw/qsp linking (r/l/q), Function library – Lenze EVS9332xS User Manual

Page 209: Function blocks

Advertising
background image

Function library

Function blocks

3.2.55

CW/CCW/QSP linking (R/L/Q)

3−157

l

EDSVS9332S−EXT EN 2.0

3.2.55

CW/CCW/QSP linking (R/L/Q)

Purpose

The FB provides a fail−safe connection for the selection of a rotation direction and the QSP function.

C0889/2

C0889/1

R/L/Q

R/L/Q-QSP

R/L/Q-R/L

R/L/Q-R

R/L/Q-L

C0885
C0886

Fig. 3−146

CW/CCW/QSP linking (R/L/Q)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

R/L/Q−R

d

C0889/1

bin

C0885

2

51

R/L/Q−L

d

C0889/2

bin

C0886

2

52

R/L/Q−QSP

d

R/L/Q−R/L

d

Function

l

After mains connection and simultaneous HIGH level at both inputs, the outputs are set as
follows:

Inputs

Outputs

R/L/Q−R

R/L/Q−L

R/L/Q−R/L

R/L/Q−QSP

1

1

0

1

l

The following truth table results if one of the inputs is set to LOW once after mains connection:

Inputs

Outputs

R/L/Q−R

R/L/Q−L

R/L/Q−R/L

R/L/Q−QSP

0

0

0

1

1

0

0

0

0

1

1

0

1

1

unchanged

unchanged

l

If both inputs are set to HIGH during operation, the values at both outputs remain unchanged.