Configuration – Lenze EVS9332xS User Manual

Page 22

Advertising
background image

Configuration

Basic configurations

2.2.2

Speed control C0005 = 1XXX (1000)

2−10

l

EDSVS9332S−EXT EN 2.0

Quick stop (QSP)

When the quick stop function is activated, the drive runs to speed 0 via the ramp set in C0105 and
executes a holding torque with a drift−free standstill. The torque limitation and the additional torque
setpoint have no effect. This means that the drive outputs the maximum possible torque (observe
settings of motor data). When the QSP request is cancelled, the drive synchronises to the current
speed.

Controller inhibit (CINH)

By setting controller inhibit the drive becomes torqueless, the machine coasts. When the controller
inhibit request is cancelled, the drive synchronises to the current speed.

Shutting down the controller via TRIP (TRIP−SET)

With LOW signal at terminal X5/E4, the controller can be shut down via the monitoring function. This
input mainly serves to evaluate external binary encoders.

The response to this input signal can be programmed.

Resetting a fault (TRIP−RESET)

With a LOW−HIGH edge at terminal X5/E5 a pending TRIP can be reset if the cause of the fault has
been eliminated.