Quick stop (qsp), Function library, Function blocks – Lenze EVS9332xS User Manual

Page 110: 23 control of the drive controller (dctrl), Function, Operation inhibited (disable), Controller inhibit (cinh), Trip−set, Trip−reset, Change of parameter set (par)

Advertising
background image

Function library

Function blocks

3.2.23

Control of the drive controller (DCTRL)

3−58

l

EDSVS9332S−EXT EN 2.0

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

DCTRL−CINH1

d

C0878/1

bin

C0870/1

2

1000

HIGH = Inhibit controller

DCTRL−CINH2

d

C0878/2

bin

C0870/2

2

1000

HIGH = Inhibit controller

DCTRL−TRIP−SET

d

C0878/3

bin

C0871

2

54

HIGH = Fault signal EEr

DCTRL−TRIP−RESET

d

C0878/4

bin

C0876

2

55

LOW−HIGH signal = TRIP reset

DCTRL−PAR*1

d

C0884/1

bin

C0880/1

2

1000

Selecting a parameter set

DCTRL−PAR*2

d

C0884/2

bin

C0880/2

2

1000

Selecting a parameter set

DCTRL−PAR−LOAD

d

C0884/3

bin

C0881

2

1000

LOW−HIGH edge = Loading a parameter set

DCTRL−QSP

d

HIGH = Drive performs quick stop

DCTRL−RDY

d

HIGH = Ready for operation

DCTRL−CINH

d

HIGH = Controller reset

DCTRL−IMP

d

HIGH = High−resistance power output
stages

DCTRL−TRIP

d

HIGH = Active fault

DCTRL−WARN

d

HIGH = Active warning

DCTRL−MESS

d

HIGH = Active message

DCTRL−FAIL

d

DCTRL−CW/CCW

d

LOW = CW rotation, HIGH = CCW rotation

DCTRL−NACT=0

d

HIGH = Motor speed < C0019

DCTRL−STAT*1

d

General status (binary coded)

DCTRL−STAT*2

d

General status (binary coded)

DCTRL−STAT*4

d

General status (binary coded)

DCTRL−STAT*8

d

General status (binary coded)

DCTRL−INIT

d

DCTRL−PARBUSY

d

HIGH = Parameter set changeover is active

DCTRL−PAR*1−O

d

Parameter set X is active (binary coded)

DCTRL−PAR*2−0

d

Parameter set X is active (binary coded)

Function

l

Quick stop (QSP)

l

Operation inhibited (DISABLE)

l

Controller inhibit (CINH)

l

TRIP−set

l

TRIP−RESET

l

Change of parameter set (PAR)

l

Controller state

3.2.23.1

Quick stop (QSP)

The drive is braked to standstill via the deceleration ramp C105 and generates a holding torque.

l

The function can be controlled by three inputs

– Control word CAN−CTRL bit 3 of CAN−IN1

– Control word AIF−CTRL bit 3 of AIF−IN

– Control word C0135 bit 3

l

All inputs are linked by an OR−operation.

l

C0136/1 displays the control word C0135

Advertising
This manual is related to the following products: