Function library, Function blocks, 40 mains failure control (mfail) – Lenze EVS9332xS User Manual

Page 165: Combination of the two methods

Advertising
background image

Function library

Function blocks

3.2.40

Mains failure control (MFAIL)

3−113

l

EDSVS9332S−EXT EN 2.0

External system for mains failure detection (934x supply module)

l

A digital output of the supply module 934x is applied to the function block MFAIL via the digital
inputs DIGIN of the controller 93XX. In the example the input X5/E4 is used. For this purpose
the signal combination must be set as follows:

– C0971 = 54 (DIGIN4 to MFAIL−FAULT)

– C0871 = 1000 (remove DCTRL−TRIP−SET from terminal X5/E4)

– Select level (HIGH or LOW active) with C0114/4

Enter the function block MFAIL into a free position of the processing table in C0465.

C0989/1

MFAIL-FAULT

MFAIL-RESET

C0971

C0972

1
0

C0988/1

C0970

C0989/2

CTRL

MFAIL-NOUT

MFAIL-N-SET

MFAIL

E1
E2
E3
E4
E5

1

0

C0114/1...5

DIGIN

DIGIN1
DIGIN2
DIGIN3
DIGIN4
DIGIN5

C0443

28

DCTRL -X5/28

X5

Fig. 3−100

Example of a mains failure detection by an external monitoring system

Combination of the two methods

l

The combination of both processes is done via an OR operation with an internal function
block. In the example, OR5 is used. For this, set the following signal combinations:

– C0688/1 = 5005 (MCTRL−DCVOLT to CMP2−IN1)

– C0688/2 = 19540 (free code C0472/20 to CMP2−IN2)

– Set function of the comparator CMP2 with C0685 = 3

– C0838/1 = 10655 (CMP2−OUT to OR5−IN1)

– C0838/2 = 54 (DIGIN5 to OR5−IN2)

– C0971 = 10570 (OR5−OUT to MFAIL−FAULT)

Enter the function blocks CMP2, OR5 and MFAIL into free positions of the processing table in C0465.

C0989/1

MFAIL-FAULT

MFAIL-RESET

C0971

C0972

1
0

C0988/1

C0970

C0989/2

CTRL

MFAIL-NOUT

MFAIL-N-SET

MFAIL

E1
E2
E3
E4
E5

1

0

C0114/1...5

DIGIN

DIGIN1
DIGIN2
DIGIN3
DIGIN4
DIGIN5

C0443

28

DCTRL -X5/28

X5

C0686

C0687

C0689/1

CMP2

CMP2-OUT

CMP2-IN1

C0689/2

CMP2-IN2

C0688/1

C0688/2

C0685

C0472/20

MCTRL-DCVOLT

OR5

³1

OR5-IN1

OR5-IN2

OR5-IN3

OR5-OUT

C0839/1

C0839/2

C0839/3

C0838/1

C0838/2

C0838/3

FIXED0

Fig. 3−101

Example of a mains failure detected by different sources

Advertising
This manual is related to the following products: