12 analog signal changeover switch (asw), Analog signal changeover switch (asw), Function library – Lenze EVS9332xS User Manual

Page 85: Function blocks

Advertising
background image

Function library

Function blocks

3.2.12

Analog signal changeover switch (ASW)

3−33

l

EDSVS9332S−EXT EN 2.0

3.2.12

Analog signal changeover switch (ASW)

Purpose

This FB changes between two analog signals.

This FB enables you to change e.g. during a winding process between an initial diameter and a
calculated diameter.

ASW1-IN1

C0812/1

1

0

C0812/2

ASW1-SET

ASW1-IN2

ASW1

ASW1-OUT

C0813

C0810/1
C0810/2

C0811

Fig. 3−29

Changeover switch for analog signals (ASW1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

ASW1−IN1

a

C0812/1

dec [%]

C0810/1

1

55

ASW1−IN2

a

C0812/2

dec [%]

C0810/2

1

1000

ASW1−SET

d

C0813

bin

C0811

2

1000

ASW1−OUT

a

ASW2-IN1

C0817/1

1

0

C0817/2

ASW2-SET

ASW2-IN2

ASW2

ASW2-OUT

C0818

C0815/1
C0815/2

C0816

Fig. 3−30

Changeover switch for analog signals (ASW2)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

ASW2−IN2

a

C0817/1

dec [%]

C0815/1

1

1000

ASW2−IN1

a

C0817/2

dec [%]

C0815/2

1

1000

ASW2−SET

d

C0818

bin

C0816

2

1000

ASW2−OUT

a

A S W 3 - I N 1

C 1 1 6 2 / 1

1

0

C 1 1 6 2 / 2

A S W 3 - S E T

A S W 3 - I N 2

A S W 3

A S W 3 - O U T

C 1 1 6 3

C 1 1 6 0 / 1
C 1 1 6 0 / 2

C 1 1 6 1

Fig. 3−31

Changeover switch for analog signals (ASW3)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

ASW3−IN2

a

C1162/1

dec [%]

C1160/1

1

1000

ASW3−IN1

a

C1162/2

dec [%]

C1160/2

1

1000

ASW3−SET

d

C1163

bin

C1161

2

1000

ASW3−OUT

a

Advertising
This manual is related to the following products: