Configuration, Basic configurations – Lenze EVS9332xS User Manual

Page 34

Advertising
background image

Configuration

Basic configurations

2.2.4

Master frequency coupling

2−22

l

EDSVS9332S−EXT EN 2.0

Features

The features describe the basic properties of this configuration. Some of them, however, can only
be used by reprogramming.

l

Resolver feedback is possible only

l

Evaluation of the setpoint (cascading factor) is possible with a factor (numerator/denominator)
for the master frequency output (and thus for all following drives)

l

Other evaluation of the setpoint is possible with a factor (numerator/denominator) for the
corresponding slave (gearbox adaptation). Can be set via an analog signal source (standard:
code C0032, C0033)

l

External torque limitation is possible

l

The QSP or CINH function in the individual drive do not influence the setpoint for the cascade.

l

Possible interventions for phase trimming and speed correction via

– LECOM,

– analog terminal or

– one of the signal sources (function blocks).

l

Message "following error limit reached" can be set via code

l

TRIP when reaching the phase controller limit

l

Speed limit of slave 0 = C0011

l

Phase controller influence can be set and switched off via the digital input

l

Homing function is possible via zero track or touch probe

l

Synchronising to a setpoint is possible via zero track or touch probe

l

Synchronising characteristic can be set via ramp−function generator