Scaling of phintx-out, Function library – Lenze EVS9332xS User Manual
Page 207
Advertising
![background image](/manuals/566111/207/background.png)
Function library
Function blocks
3.2.53
Phase integrator (PHINT)
3−155
l
EDSVS9332S−EXT EN 2.0
3.2.53.4
Scaling of PHINTx−OUT
Mathematical description of PHINTx−OUT:
PHINTx
* OUT[inc] + PHINTx * IN[rpm] @ t[s] @ 65536[incńrev.]
t
Integration time
Example:
You want to determine the count of the integrator with a certain speed at the input and a certain
integration time.
l
Given values:
– PHINTx−IN = 1000 rpm
– t = 10 s
– Start value of the integrator = 0
l
Solution:
– Conversion of PHINTx−IN:
1000 rpm
+ 1000 rev.
60 s
– Calculation of PHINTx−OUT:
PHINTx
* OUT + 1000 rev.
60 s
@ 10 s @ 65536 inc
rev.
+ 10922666 inc
Advertising
This manual is related to the following products: