Setting controller inhibit, Function library, Function blocks – Lenze EVS9332xS User Manual

Page 90

Advertising
background image

Function library

Function blocks

3.2.13

Holding brake (BRK)

3−38

l

EDSVS9332S−EXT EN 2.0

3.2.13.3

Setting controller inhibit

Setting controller inhibit may for instance be required in the case of a fault (LU, OU, ...).

Function

When the controller is inhibited (CINH), the BRK1−OUT signal is set to HIGH immediately. The drive
is then braked via the mechanical brake.

If the fault is eliminated quickly, i.e. the controller inhibit (CINH) is reset before the actual speed falls
below the threshold value BRK1−Nx, the BRK1−OUT signal is set to LOW immediately. The drive is
synchronised to the actual speed and follows its setpoint.

If the value falls below the threshold, the drive starts as described under "Release brake".

C0196

t

t

BRK1−CINH

MCTRL−NACT

BRK1−OUT

|BRK1−Nx|

BRK1−QSP

MCTRL−MACT

MCTRL−MACT = C0244

BRK1−M−STORE

t

t

t

t

Fig. 3−34

Brake control with CINH