Homing modes, Function library – Lenze EVS9332xS User Manual

Page 212

Advertising
background image

Function library

Function blocks

3.2.56

Homing function (REF)

3−160

l

EDSVS9332S−EXT EN 2.0

3.2.56.2

Homing modes

The home position is defined via

l

the homing mode C0932

l

the signal edge of the zero pulse or touch probe signal C0933

l

the home position offset C0934

)

Note!

For position feedback via resolver, the zero position (depending on the resolver
attachment to the motor) is used instead of the zero pulse. Accordingly, the touch
probe angle is used for homing via touch probe.

Homing to zero pulse/zero position with reference switch

The home position is after the negative edge of the reference switch REF−MARK, at the next zero
pulse/zero position plus the home position offset:

l

Mode 0 (C0932 = 0):

– Move to the home position in CW rotation.

– Enter positive home position offset C0934.

Referenzpunkt

Startpunkt

Fahrtrichtung

MCTRL-PHI-ACT

REF-MARK

Fahrtstrecke

C0934

Fig. 3−149

Homing with zero pulse/zero position; approaching the home position in CW rotation

l

Mode 1 (C0932 = 1):

– Move to the home position in CCW rotation.

– Enter negative home position offset C0934.

Referenzpunkt

Startpunkt

Fahrtrichtung

Fahrtstrecke

C0934

MCTRL-PHI-ACT

REF-MARK

9300STD219

Fig. 3−150

Homing with zero pulse/zero position; approaching the home position in CW rotation