Function library, Function blocks, Stop – Lenze EVS9332xS User Manual

Page 116

Advertising
background image

Function library

Function blocks

3.2.24

Master frequency input (DFIN)

3−64

l

EDSVS9332S−EXT EN 2.0

Signal adaptation

Finer resolutions than the power−of−two format can be realised by connecting an FB (e.g. CONV3 or
CONV4).

Example:

The FB CONV3 converts the speed signal into a quasi−analog signal. The conversion is done
according to the formula:

CONV3−OUT [%]

+ f [Hz] @

0, 4

Number of increments from C0425

@ C0950

C0951

CONV3

CONV3-OUT

CONV3-IN

C0953

C0952

C0950

C0951

C0425

C0427

DFIN

DFIN-OUT

C0426

X9

Fig. 3−62

Digital frequency input (DFIN) with connected converter

(

STOP!

If C0540 = 0, 1, 2, 3 and a feedback system C0025 > 10, you must not use the
digital frequency input X9 anymore.