Trip-reset, Function library – Lenze EVS9332xS User Manual

Page 112

Advertising
background image

Function library

Function blocks

3.2.23

Control of the drive controller (DCTRL)

3−60

l

EDSVS9332S−EXT EN 2.0

3.2.23.5

TRIP−RESET

Resets a pending trip as soon as the cause of malfunction has been removed. If the cause is still
active, no reaction occurs.

l

The function can be controlled by four inputs

– Control word CAN−CTRL bit 11 of CAN−IN1

– Control word AIF−CTRL bit 11 of AIF−IN

– Control word C0135 bit 11

– Free input DCTRL−TRIP−RESET

l

All inputs are linked by an OR−operation.

l

The function can only be performed by a LOW−HIGH edge of the signal resulting from the OR
operation.

l

C0136/1 displays the control word C0135

)

Note!

If one of the inputs is set to HIGH, it is not possible that a LOW−HIGH edge will
occur on the resulting signal.

Advertising