Configuration

Basic configurations

2.2.6

Angular synchronism

2−29

l

EDSVS9332S−EXT EN 2.0

Use of TOUCH−PROBE

Besides the zero pulses of the inputs X9 and the corresponding feedback system, the zero pulse
evaluation can also be derived from the digital inputs X5/E4 (actual value) and X5/E5 (setpoint). The
function is switched from zero pulse evaluation of the encoder (or resolver) to the evaluation of the
inputs X5/E4 and X5/E5 by C0532 = 2.

IMPORTANT:

The inputs X5/E4 and X5/E5 are assigned with TRIP−Set or TRIP−Reset as standard. In this case, the
input terminals must be removed from the function block DCTRL (drive control).

Use of zero pulse for the setpoint and TOUCH−PROBE for the actual value

The zero pulses can also be evaluated via a zero pulse at setpoint input X9 and a TOUCH−PROBE
input X5/E4 (actual value). The function is switched on with C0532 = 3.

X7

R

M

1:5

Master

Slave

R

M

Touch probe

X9

Ctrl. enable

V

withdrawal

9300 Master

9300 slave

28

E4

E5

39

A1

A4

A2

Gearbox

Gearbox

Stretch factor

X10

X10

=

+

1

2

X7

n

act

=0

1:5

Ctrl. enable

28

E4

E5

39

A1

A4

A2

n

act

=0

Fig. 2−5

Example for using TOUCH−PROBE