Function library, Function blocks, 63 multi−axis synchronisation (sync1) – Lenze EVS9332xS User Manual

Page 229

Advertising
background image

Function library

Function blocks

3.2.63

Multi−axis synchronisation (SYNC1)

3−177

l

EDSVS9332S−EXT EN 2.0

Axis synchronisation via system bus (CAN)

The system bus (CAN) transmits the sync telegram and the process signals.

Application examples:

l

Selection of cyclic, synchronised position setpoint information for multi−axis positioning via the
system bus (CAN).

1 6 b i n a r y

s i g n a l s

1 6 B i t

L o w W o r d

1 6 B i t

H i g h W o r d

1 6 B i t

C A N - I N 3 . W 3

C A N - I N 3 . D 1

B

yt

e

3,

4

B

yt

e

5,

6

S y t e m b u s

X 4

C A N - I N 3

C A N - I N 3 . B 3 1

C A N - I N 3 . B 1 6

C A N - I N 3 . B 3 0

C A N - I N 3 . B 1 7

...

C 0 8 6 7 / 3

C 0 8 6 6 / 1 0

C 0 8 6 3 / 6

P O S - P S E T - E X T

S Y N C 1

S Y N C 1 - I N 1

S Y N C 1 - I N 2

S Y N C 1 - I N 3

S Y N C 1 - S T A T

C 1 1 2 7

C 1 1 2 8

C 1 1 2 9

C 1 1 2 4

C 1 1 2 5

C 1 1 2 6

C 1 1 2 1

C 1 1 2 2

C 1 1 2 0

X 4

S Y N C 1 - O U T 1

S Y N C 1 - O U T 2

S Y N C 1 - O U T 3

C L K

Fig. 3−162

Example for linking the FB SYNC1

Axis synchronisation via terminal control (X5/E5)

The transmission paths for the sync signal and the process signals are separated.

l

The process signals are connected via a freely selectable input channel (e. g. AIF interface, DF
input).

l

The sync signal is injected via terminal X5/E5.

Application examples:

l

Selection of cyclic, synchronised position setpoint information for multi−axis positioning via
other bus systems (e. g. Interbus).

l

Synchronisation of the internal processing cycles of the FB to higher−level process controls.

Advertising
This manual is related to the following products: