Function library

Working with function blocks

3.1.2

Elements of a function block

3−5

l

EDSVS9332S−EXT EN 2.0

Configuration code

Configures the input with a signal source (e. g. terminal signal, control code, output of an FB, ...).
Inputs with identical codes are distinguished by the attached subcode (Cxxxx/1). These codes are
configured via the subcode.

It is not possible to connect an input with several signal sources.

Display code

Displays the current input value. Inputs with identical codes are distinguished by the attached
subcode (Cxxxx/1). These codes are displayed via the subcode.

Display codes cannot be processed.

Function

Represents the mathematical function as a block diagram (see Fig. 3−1).

Parameterisation code

Adaptation of the function or behaviour to the drive task. Possible settings are described in the text
editor and / or the line diagrams. (

¶ 3−12)

Output symbol

Designates the signal type. Connections with inputs of the same signal type are possible. (

3−3)

Each output is defined by a selection number. The selection numbers are divided into selection lists
(1 ... 4) according to the different signal types.

An output is linked to an input by the selection numbers.

Example:

(FCNT1, see Fig. 3−1)

l

FCNT1−OUT

¢ selection number 6400 (analog signal, selection list 1).

l

FCNT1−EQUAL

¢ selection number 6400 (digital signal, selection list 2).

)

Note!

Only outputs brought out of the FB can be configured.

Output name

Consists of the FB name and a designation. Outputs with the same function are distinguished by the