59 s-shaped ramp function generator (srfg), S−shaped ramp function generator (srfg), Function library – Lenze EVS9332xS User Manual

Page 219: Function blocks, 59 s−shaped ramp function generator (srfg)

Advertising
background image

Function library

Function blocks

3.2.59

S−shaped ramp function generator (SRFG)

3−167

l

EDSVS9332S−EXT EN 2.0

3.2.59

S−shaped ramp function generator (SRFG)

Purpose

The function block serves to direct the input signal via a jerk−limited ramp generator (S shape) in order
to avoid setpoint step−changes.

C1040
C1041

C1045/1

SRFG1

SRFG1-OUT

SRFG1-IN

C1045/2

1

0

SRFG1-SET

C1046

SRFG1-LOAD

C1042

C1043

C1044

SRFG1-DIFF

Fig. 3−156

S−shaped ramp function generator (SRFG1)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

SRFG1−IN

a

C1045/1

dec [%]

C1042

1

input

SRFG1−SET

a

C1045/2

dec [%]

C1043

1

Starting value for the ramp function generator, will be
accepted if SRFG1−LOAD = High

SRFG1−LOAD

d

C1046

bin

C0144

2

HIGH = accepts the value at SRFG1−SET and provides it
at SRFG1−OUT; SRFG1−DIFF always remains at 0 %

ББББББ

ББББББ

SRFG1−OUT

БББ

БББ

a

БББ

БББ

БББББ

БББББ

ББББ

ББББ

ББ

ББ

ББББББББББББ

ББББББББББББ

Output limited to

±100 %

ББББББ

ББББББ

SRFG1−DIFF

БББ

БББ

a

БББ

БББ

БББББ

БББББ

ББББ

ББББ

ББ

ББ

ББББББББББББ

ББББББББББББ

Output limited to

±100 %, provides the acceleration of

the ramp function generator

SRFG1−LOAD

l

Via digital input SRFG1−LOAD, the ramp function generator is loaded (set) with the signal from
SRFG1−SET.

l

This value is immediately accepted, i.e. there is no acceleration/deceleration via S shape (the
output skips to this value).

l

As long as SRFG−LOAD = HIGH, the ramp function generator remains inhibited.

Advertising