Function library, Function blocks – Lenze EVS9332xS User Manual

Page 146

Advertising
background image

Function library

Function blocks

3.2.34

Freely assignable input variables (FEVAN)

3−94

l

EDSVS9332S−EXT EN 2.0

Example 2 (only for FIX32 format without % scaling):

Task:

l

C0473/1 = 1000. Write this value to C0011.

Configuration:

l

Connect FEVAN1−IN (C1096) with FCODE−473/1 (19551).

l

Connect FEVAN1−LOAD (C1097/1) with FCODE−471.B0 (19521).

Parameter setting:

l

Set C1091 = 11 (

¢ C0011)

l

Set C1092 = 0 (no subcode available)

l

Set C1093 = 1.0

l

Set C1094 = 0.0001 (no decimal position)

l

Set C1095 = 0 (no offset).

The source code has no unit. The scaling factor is dropped.

Calculation:

FEVAN1–IN

@

1

10000

@ C1093

C1094

) C1095 + C0011 [rpm]

Scaling factor

1000

@

1

10000

@

1, 0

0.0001

) 0 + 1000 rpm

Control:

l

Set C0471.B0 = 1 (

¢ 00000001h) so that the data are transmitted to the target code.

Display:

l

C0011 displays the value 1000 rpm.

The other formats are calculated with the following formula:

FEVAN1–IN

@ C1093

C1094

) C1095 + x

Advertising