Configuration – Lenze EVS9332xS User Manual

Page 24

Advertising
background image

Configuration

Basic configurations

2.2.3

Torque control with speed limitation 4000

2−12

l

EDSVS9332S−EXT EN 2.0

Speed setpoint (speed limits)

The speed limitation is carried out via the n−controllers in the MCTRL function block. The first speed
controller (main speed controller) is the upper speed limit and the second speed controller is the lower
speed limit.

Example:

The speed can be within a range of

"5000 rpm.

+5000rpm (CW rotation) is the upper limit and −5000 rpm (CCW rotation) is the lower limit. The
parameter setting is explained below.

The upper speed limit is provided via the analog terminal X6/1,2. This input can be used as a speed
setpoint e.g. in the threading in winding systems, wire−drawing machines, etc.

Please observe:

l

The torque cannot exceed the input at terminal X6/3,4.
The input voltage must be set to 10 V, if necessary.

l

The value cannot fall below the lower speed limit (code C0472/4).

l

The setpoint speed is conditioned in the same way as for speed control (C0005=1000).

Reference values:

l

When a master voltage of +10 V is entered, the setting under C0011 is the upper speed limit
(CW rotation).

l

If −10 V are provided, C0011 is the upper speed limit in CCW rotation.

The lower speed limit is entered under code C0472/4.

Reference values:

l

If −100% are entered, the setting under C0011 is the lower speed limit in CCW rotation.

Quick stop (QSP) and controller inhibit (CINH)

See quick stop (QSP) and controller inhibit (CINH).

TRIP−SET and TRIP−RESET

See TRIP−SET and TRIP−RESET.