Function library

Function blocks

3.2.23

Control of the drive controller (DCTRL)

3−61

l

EDSVS9332S−EXT EN 2.0

3.2.23.6

Parameter set changeover (PAR)

The controller loads and operates with the parameter set selected.

l

The parameter set to be loaded is selected via the inputs DCTRL−PAR*1 and DCTRL−PAR*2.
The inputs are binary coded (1 from 4).

PAR*2

PAR*1

Selected parameter set

0

0

Parameter set 1

0

1

Parameter set 2

1

0

Parameter set 3

1

1

Parameter set 4

l

A LOW−HIGH edge at the input DCTRL−PAR−LOAD enables the controller to switch to the new
parameter set.

)

Note!

If the parameter set to be loaded via the terminal X5/Ex is already selected before
switching on the supply voltage, there is no need for the LOW−HIGH edge at the
input DCTRL−PAR−LOAD. In this case, the controller loads the selected parameter
set automatically.

l

The controller is not ready for operation for approx. one second. During this period, DCTRL−
RDY displays LOW.

3.2.23.7

Controller state

The binary−coded status of the controller is output via DCTRL−STAT*x. These outputs are connected
to the STAT function block inside the device.

The status can be evaluated via the status word C0150, CAN status word and AIF status word.

STAT*8

STAT*4

STAT*2

STAT*1

Action of the controller

0

0

0

0

Initialisation after the supply voltage has been connected

0

0

0

1

Lock mode, restart protection is active C0142

0

0

1

1

Drive is in controller inhibit mode

0

1

1

0

Controller enabled

0

1

1

1

The release of a monitoring function resulted in a "message"

1

0

0

0

The release of a monitoring function resulted in a "trip"

3.2.23.8

Standstill message (DCTRL−NACT=0)

The standstill message (DCTRL−NACT=0) is set immediately if the actual speed (MCTRL−NACT) falls
below the speed threshold (without any hysteresis effect) set in C0019.

The standstill message disappears if the actual speed (MCTRL−NACT) exceeds the sum of the speed
threshold set in C0019 and the hysteresis. The hysteresis amounts to 1 % of the maximum speed
set in C0011.

)

Note!

The hysteresis ensures a stable standstill signal even if the actual speed value jitters.