Output of an analog signal, Output of a speed signal, Function library – Lenze EVS9332xS User Manual

Page 119: Function blocks

Advertising
background image

Function library

Function blocks

3.2.25

Digital frequency output (DFOUT)

3−67

l

EDSVS9332S−EXT EN 2.0

3.2.25.2

Output of an analog signal

For this purpose, set code C0540 = 0. The value applied at input DFOUT−AN−IN is converted into a
frequency.

Transfer function

f [Hz]

+ DFOUT * AN * IN [%] @

No. of increments from C0030

100

@ C0011

60

Example:

DFOUT−AN−IN = 50 %

C0030 = 3, this corresponds to a number of increments of 2048 inc/rev.

C0011 = 3000 rpm

f [Hz]

+ 50 % @ 2048

100

@ 3000

60

+ 51200 Hz

Generating a zero pulse

An artificial zero pulse can be generated for the output frequency.

1. Activate the function through a LOW

® HIGH edge at the input DFOUT−SYN−RDY.

2. A LOW

® HIGH edge at terminal X5/E5 causes the generation of the zero pulse after 360°.

After this, every 360° a zero pulse is generated according to the setting in C0030.

3. The zero pulse is automatically shifted by the value C0545.

)

Note!

This procedure must be done after every mains switching.

3.2.25.3

Output of a speed signal

l

Set C0540 = 1.

– This setting only converts the value at input DFOUT−DF−IN into a frequency.

Transfer function

f

[Hz] + DFOUT−DF−IN [rpm] @

No. of increments from C0030

60

Example:

DFOUT−DF−IN = 3000 rpm

C0030 = 3, this corresponds to a number of increments of 2048 inc/rev.

f

[Hz] + 3000 [rpm] @ 2048

60

+ 102400 [Hz]

Generating a zero pulse

An artificial zero pulse can be generated for the output frequency.

1. Set input DFOUT−SYN−RDY = edge from LOW

® HIGH.

2. A LOW−HIGH edge at terminal X5/E5 causes the generation of the zero pulse after 360°. After

this, every 360° a zero pulse is generated according to the setting in C0030.

3. The zero pulse can be shifted by +360° via C0545 (65536 inc = 360°).