Function library

Function blocks

3.2.43

Motor potentiometer (MPOT)

3−126

l

EDSVS9332S−EXT EN 2.0

Tir

Tir

Tir

Tif

MPOT1−UP

MPOT1−DOWN

C0260

C0261

0

+

MPOT1−OUT

Fig. 3−108

Control signals of the motor potentiometer

In addition to the digital signals MPOT1−UP and MPOT1−DOWN another digital input exists
(MPOT1−INACT). The input MPOT1−INACT is used to activate or deactivate the motor potentiometer
function. Logic 1 at this input deactivates the motor potentiometer function. The input
MPOT1−INACT has priority over the inputs MPOT1−UP and MPOT1−DOWN.

When the motor potentiometer is deactivated, the motor potentiometer output (MPOT1−OUT)
follows the function set under C0264. The following functions can be set under C0264:

Advertising