Stop!

It is possible to load predefined basic configurations via code C0005. If you load a
configuration via C0005, the assignment of all inputs and outputs will be overwritten
with the corresponding basic configuration.

Adapt the function assignment to the wiring.

The internal signal processing is adapted to the drive task by selecting a predefined basic
configuration. You can, for instance, use the Lenze setting for speed control.

l

A detailed description of the basic configurations with terminal assignments, signal flow
diagrams, and application examples can be found in chapter "Application examples".

l

Before loading a basic configuration via C0005, the controller must be inhibited.

Several predefined signal configurations can be loaded by using code C0005. The selection numbers
have the following meaning:

C0005 =

X

X

X

X

Control
0 − Terminal control
1 − Control via LECOM A/B/LI
3 − Control via AIF (INTERBUS,PROFIBUS)
5 − Control via system bus (CAN)

Voltage source for the control terminals
0 − External supply of control terminals
1 − Internal supply of control terminals

Additional function
0 − No additional function
1 − Brake control via digital output X5/A2
9 − At quick stop (QSP) deceleration of the complete drive system to zero speed in an angle−controlled
mode

Basic function
1 − Speed control
4 − Torque control with speed limitation
5 − Master for digital frequency coupling
6 − Slave on digital frequency bus
7 − Slave on digital frequency cascade