Function library, Function blocks – Lenze EVS9332xS User Manual
Page 79
Advertising
Function library
Function blocks
3.2.7
AND operation (AND)
3−27
l
EDSVS9332S−EXT EN 2.0
Function
ANDx−IN1
ANDx−IN2
ANDx−IN3
ANDx−OUT
0
0
0
0
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
1
The function corresponds to a series connection of normally−open contacts in a contactor control.
ANDx−IN1
ANDx−IN2
ANDx−IN3
ANDx−OUT
Fig. 3−20
AND function as a series connection of normally−open contacts
Tip!
If only two inputs are required, use the inputs ANDx−IN1 and ANDx−IN2. Assign the input ANDx−IN3
to the signal source FIXED1 via the configuration code.