Function library, Function blocks, 12 analog signal changeover switch (asw) – Lenze EVS9332xS User Manual

Page 86

Advertising
background image

Function library

Function blocks

3.2.12

Analog signal changeover switch (ASW)

3−34

l

EDSVS9332S−EXT EN 2.0

A S W 4 - I N 1

C 1 1 6 7 / 1

1

0

C 1 1 6 7 / 2

A S W 4 - S E T

A S W 4 - I N 2

A S W 4

A S W 4 - O U T

C 1 1 6 8

C 1 1 6 5 / 1
C 1 1 6 5 / 2

C 1 1 6 6

Fig. 3−32

Changeover switch for analog signals (ASW4)

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

ASW4−IN2

a

C1167/1

dec [%]

C1165/1

1

1000

ASW4−IN1

a

C1167/2

dec [%]

C1165/2

1

1000

ASW4−SET

d

C1168

bin

C1166

2

1000

ASW4−OUT

a

Function

This FB is controlled via the binary input. Depending on the input signal, different signals are sent to
the output:

l

If a HIGH signal is applied at the binary input, the signal which is applied at the ASWx−IN2
input is sent to the output.

l

If a LOW signal is applied, the signal which is applied at the ASW−IN2 input is sent to the
output.