3 connecting function blocks, Connecting function blocks, Function library – Lenze EVS9332xS User Manual

Page 58: Working with function blocks, Stop, General rules, Assign a signal source to an input, One input can have only one signal source, Only signals of the same type can be connected

Advertising
background image

Function library

Working with function blocks

3.1.3

Connecting function blocks

3−6

l

EDSVS9332S−EXT EN 2.0

3.1.3

Connecting function blocks

General rules

l

Assign a signal source to an input.

l

One input can have only one signal source.

l

Inputs of different function blocks can have the same signal source.

l

Only signals of the same type can be connected.

(

Stop!

Existing connections which are not required must be removed by reconfiguration.
Otherwise the drive cannot perform the desired function.

AND1

&

AND1−IN1

AND1−IN2

AND1−IN3

AND1−OUT

C0821/1

C0821/2

C0821/3

C0820/1

C0820/2

C0820/3

OR1

|1

OR1−IN1

OR1−IN2

OR1−IN3

OR1−OUT

C0831/1

C0831/2

C0831/3

C0830/1

C0830/2

C0830/3

NOT1

1

NOT1−OUT

NOT1−IN

C0841

NOT2

1

NOT2−OUT

NOT2−IN

C0843

C0840

C0842

t

0

DIGDEL1−IN

C0724

DIGDEL1−OUT

DIGDEL1

C0721

C0720

C0723

Connection not possible

Connection is possible

X

Fig. 3−2

Correct connection of function blocks