2 elements of a function block, Elements of a function block, Function library – Lenze EVS9332xS User Manual

Page 56: Working with function blocks

Advertising
background image

Function library

Working with function blocks

3.1.2

Elements of a function block

3−4

l

EDSVS9332S−EXT EN 2.0

3.1.2

Elements of a function block

FCNT1−CLKUP

C1102/1

C1102/2

FCNT1−LOAD

C1102/3

C1104/3

FCNT1−OUT

FCNT1

C1101/1

C1101/2

C1103/2

C1103/1

C1104/2

FCNT1−LD−VAL

FCNT1−CLKDWN

C1104/1

C1100

CTRL

FCNT1−CMP−VAL

FCNT1−EQUAL

Input symbol

Configuration code

Display code

Function

Input name

FB name

Output name

Output symbol

Parameterisation code

Fig. 3−1

Structure of a function block (FB) using the example of FCNT1

FB name

Clearly identifies the FB. The FB name is followed by a number distinguishing the function of the FB.

Each FB is defined via its selection number. For calculating the FB the input of the selection number
into the processing table is always required. (

¶ 3−10)

The selection numbers are listed in selection list 5.

Example:

(FCNT1, see Fig. 3−1)

l

FCNT1

¢ selection number 6400 (selection list 5).

Input symbol

Indicates the signal type which can be used as a signal source for this input. (

3−3)

)

Note!

Only inputs led through the FB can be configured.

Input name

Consists of the FB name and a designation. Inputs with the same function are distinguished by the
number that is added to the designation.

Advertising
This manual is related to the following products: