Function library
Function blocks
3.2.26
Digital frequency ramp function generator (DFRFG)
3−72
l
EDSVS9332S−EXT EN 2.0
3.2.26.4
RESET
DFRFG−RESET = HIGH:
l
Resets setpoint phases which are internally added.
l
Activates the profile generator.
l
HIGH−LOW edge at DFRFG−RESET: Detecting the setpoint phase.
3.2.26.5
Detect phase difference
Monitoring the phase difference between input DFRFG−IN and output DFRFG−OUT.
l
Set limit value of monitoring via C0754.
l
Activates the monitoring: DFRFG−FAIL = HIGH
l
Storing the signal until DFRFG−RESET = HIGH.
l
The profile generator can accept a phase difference of up to ±2140000000 inc (= 32000
revolutions).