Function library

Function blocks

3.2.26

Digital frequency ramp function generator (DFRFG)

3−72

l

EDSVS9332S−EXT EN 2.0

3.2.26.4

RESET

DFRFG−RESET = HIGH:

l

Resets setpoint phases which are internally added.

l

Activates the profile generator.

l

HIGH−LOW edge at DFRFG−RESET: Detecting the setpoint phase.

3.2.26.5

Detect phase difference

Monitoring the phase difference between input DFRFG−IN and output DFRFG−OUT.

l

Set limit value of monitoring via C0754.

l

Activates the monitoring: DFRFG−FAIL = HIGH

l

Storing the signal until DFRFG−RESET = HIGH.

l

The profile generator can accept a phase difference of up to ±2140000000 inc (= 32000
revolutions).