Application examples

4.5

Master frequency bus − slave − drive (C0005 = 6000)

4−12

l

EDSVS9332S−EXT EN 2.0

4.5

Master frequency bus − slave − drive (C0005 = 6000)

Tip!

The most important settings can be found in the menu: "Short Setup / Speed mode" of the operating
module or in the menu "Short setup / Speed mode" in Global Drive Control.

Enter motor type (contains all nameplate data of the motor)

C0173

xxx

Enter UG limit (mains voltage)

C0086

000

Enter motor data manually

Enter maximum motor current

C0022 xxxA Determine

Imax

Enter controller configuration

C0005

6000

Select digital frequency cascade − slave

C0025

xxx

Enter feedback system

Speed setpoint settings

C0011

xxx rpm

Determine max. speed

C0032

xxx

Numerator of gearbox factor

C0033

xxx

Denominator of gearbox factor

C0425

xxx

Adjust encoder constant to the master

Application parameters

C0070

xxx

Vp n−controller

C0071

xxx

Tn n−controller

C0254

xxx

Gain of the angle controller

Save parameters

C0003

xxx

Save all parameters