Release of the fixset1 setpoints, Function library, Function blocks – Lenze EVS9332xS User Manual

Page 148

Advertising
background image

Function library

Function blocks

3.2.35

Fixed setpoints (FIXSET)

3−96

l

EDSVS9332S−EXT EN 2.0

3.2.35.1

Release of the FIXSET1 setpoints

Number of the fixed setpoints required

Number of inputs to be assigned

1

at least 1

1 ... 3

at least 2

4 ... 7

at least 3

8 ... 15

4

System for decoding the binary input signals:

Output signal
FIXSET1−OUT =

1st input

FIXSET1−IN1

2nd input

FIXSET1−IN2

3rd input

FIXSET1−IN3

4th input

FIXSET1−IN4

FIXSET1−Ain

0

0

0

0

C0560/1

1

0

0

0

C0560/2

0

1

0

0

C0560/3

1

1

0

0

C0560/4

0

0

1

0

C0560/5

1

0

1

0

C0560/6

0

1

1

0

C0560/7

1

1

1

0

C0560/8

0

0

0

1

C0560/9

1

0

0

1

C0560/10

0

1

0

1

C0560/11

1

1

0

1

C0560/12

0

0

1

1

C0560/13

1

0

1

1

C0560/14

0

1

1

1

C0560/15

1

1

1

1