Configuration

Basic configurations

2.2.4

Master frequency coupling

2−19

l

EDSVS9332S−EXT EN 2.0

Features

The features describe the basic properties of this configuration. Some of them, however, can only
be used by reprogramming.

l

Hardware connection of the master frequency input with the master frequency output (so that
any number of drives can be connected in series)

l

Setpoint evaluation with a factor (numerator/denominator) for the corresponding slave
(gearbox adaptation). Can be set via an analog signal source:

– Terminal,

– code or

– function block.

l

external torque limitation is possible

l

QSP function for the individual drive. The setpoint is continued to be output.

l

CINH function for the individual drive. The setpoint is continued to be output to the master
frequency output.

l

Possible interventions for phase trimming and speed correction via

– LECOM

– analog terminal

– one of the signal sources (function blocks)

l

Message "following error limit reached" can be set via code

l

TRIP when reaching the phase controller limit

l

Speed limit of slave 0 = C0011

l

Phase controller influence can be set and switched off via the digital input

l

Homing function is possible via zero track or touch probe

l

Synchronising to a setpoint is possible via zero track or touch probe

l

Synchronising characteristic can be set via ramp−function generator