Application examples – Lenze EVS9332xS User Manual

Page 245

Advertising
background image

Application examples

4.3

Torque control with speed limitation (C0005 = 4000)

4−7

l

EDSVS9332S−EXT EN 2.0

4.3

Torque control with speed limitation (C0005 = 4000)

Tip!

The most important settings can be found in the menu: "Short Setup / Speed mode" of the operating
module or in the menu "Short setup / Speed mode" in Global Drive Control.

Enter motor type (contains all nameplate data of the motor)

C0173

xxx

Enter UG limit (mains voltage)

C0086

000

Enter motor data manually

Enter maximum motor current

C0022 xxxA Determine

Imax

Enter controller configuration

C0005

4000

Select torque control

C0025

xxx

Enter feedback system

Speed setpoint settings

C0011

xxx rpm

Determine max. speed

C0105

xxx s

Set QSP deceleration time

Speed limitation

C0472/4

xxx % nmax

Determine lower speed limit

Application parameters

C0070

xxx

Vp n−controller

C0071

xxx

Tn n−controller

Save parameters

C0003

xxx

Save all parameters