Function library

Function blocks

3.2.34

Freely assignable input variables (FEVAN)

3−91

l

EDSVS9332S−EXT EN 2.0

Function

l

Conversion of the read data via:

– Numerator, denominator.

– Offset.

l

Selection of a target code for the read data.

Codes for the conversion of the read data and for the selection of the target code

Selection of the target code

Function block

Numerator

Denominator Offset

Code

Subcode

Examples

FEVAN1

C1093

C1094

C1095

C1091

C1092

FEVAN2

C1503

C1504

C1505

C1501

C1502

Data transmission

FEVANx-FAIL

FEVANx-BUSY

FEVANx-LOAD

Correct transmission

Wrong transmission

Fig. 3−86

Signal flow

Transmission errors may occur if

l

no target code is available,

l

no target subcode is available,

l

the data transmitted are out of the target code limits,

l

the target code is inhibited since it may only be written if the controller is inhibited. Inhibit the
controller (see code table).

Cyclic data transmission

F E V A N 1 - I N

C 1 0 9 8

C 1 0 9 6

C 1 0 9 3
C 1 0 9 4

C T R L

+

+

C 1 0 9 5

S & H

C 1 0 9 9

F E V A N 1 - L O A D

C 1 0 9 7

C 1 0 9 0

C o d e / S u b c o d e

( C x x x x / y y y )

C 1 0 9 2

C 1 0 9 1

F E V A N 1 - B U S Y

F E V A N 1 - F A I L

F E V A N 1

N O T 1

1

N O T 1 - O U T

N O T 1 - I N

C 0 8 4 1

C 0 8 4 0

Fig. 3−87

Example for a cyclic data transmission to a target code