17 signal conversion (conv), Signal conversion (conv), Function library – Lenze EVS9332xS User Manual

Page 99: Function blocks

Advertising
background image

Function library

Function blocks

3.2.17

Signal conversion (CONV)

3−47

l

EDSVS9332S−EXT EN 2.0

3.2.17

Signal conversion (CONV)

Purpose

These function blocks can be used to standardize signals or signal types or to convert signal types
into different signal types.The conversion is very precise by providing the conversion factor as
numerator and denominator.

CONV1

CONV1

CONV1-OUT

CONV1-IN

C0943

C0942

C0940
C0941

Fig. 3−42

Function block CONV1

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

CONV1−IN

a

C0943

dec [%]

C0942

1

1000

CONV1−OUT

a

Limited to ±199.99 %

This function block is used to multiply or divide analog signals.

The conversion is done according to the formula:

CONV1–OUT

+ CONV1–IN @ C0940

C0941

Example:

An analog signal is to be multiplied with 1.12.
For this, enter C0940 = 112 and C0941 = 100.

CONV2

CONV2

CONV2-OUT

CONV2-IN

C0948

C0947

C0945
C0946

Fig. 3−43

Function block CONV2

Signal

Source

Note

Name

Type

DIS

DIS format

CFG

List

Lenze

CONV2−IN

a

C0948

dec [%]

C0947

1

1000

CONV2−OUT

a

Limited to ±199.99 %

This function block is used to multiply or divide analog signals.

The conversion is done according to the formula:

CONV2–OUT

+ CONV2–IN @ C0945

C0946

Advertising