Error codes, Fault codes, Error codes fault codes – Rockwell Automation 2097-Vxxx Kinetix 350 Single-axis EtherNet/IP Servo Drive User Manual User Manual

Page 113

Advertising
background image

Rockwell Automation Publication 2097-UM002C-EN-P - December 2013

113

Troubleshoot the Kinetix 350 Drive Chapter 7

Error Codes

The following list helps you resolve memory anomalies.

When a fault is detected, the status indicator displays an E and a two-digit error
code until the anomaly is cleared.

Fault Codes

These fault code tables are designed to help you resolve anomalies. When a fault
is detected, the four-digit status indicator scrolls the display message. This is
repeated until the fault code is cleared.

Table 42 - Fault Code Summary

Error

Code

Anomaly

Possible Cause

Action/Solution

E38

Memory module error.

Bad memory module.

Replace memory module.

E76

Blank memory module.

A Blank MEM module has been
inserted into the drive.

Push and hold the drive's enter key
(bottom most red button) on the drive's
front display until the drive shows
"bUSY". This will make the drive format
the blank memory module for usage with
the drive.

Fault Code Type

Description

S xx

Conditions that prevent the drive from enabling, see

Table 43.

Scxx

F xx

Standard axis fault, see

Table 44

and

Table 45.

Fcxx

Lxxx

Unrecoverable errors that occur during the boot process.
Return drive to Rockwell Automation.

Pxxx

Unrecoverable errors that occurred during the Power on Self Test (POST). Return drive
to Rockwell Automation.

Icxx

Anomalies that prevent normal operation and occur during the initialization process.

nFxx

Anomalies that prevent normal operation of the drive. Node Fault. This type of fault
that impacts the servo drive not just the axis of motion.

Table 43 - S xx and Scxx Start Inhibit Codes

Four-digit Display

RSLogix 5000

Fault Message

Problem or Symptom

Potential Cause

Possible Resolution

S 01

Axis enable input.

The axis enable input is
deactivated.

Axis Enable Input is not active.

Check wiring and 24V source for drive

ENABLE Input.

Disable enableInputChecking attribute

by using a message instruction.

Advertising