Rockwell Automation Publication 2097-UM002C-EN-P - December 2013

63

Connect the Kinetix 350 Drive System Chapter 4

Wiring the Kinetix 350 Drive
Connectors

This section provides examples and wiring tables to assist you in making
connections to the Kinetix 350 drive.

Wire the Safe Torque-off (STO) Connector

For the safe torque-off (STO) connector pinouts, feature descriptions, and wiring
information, refer to Chapter 6 on

page 101

.

Wire the Back-up Power (BP) Connector

Table 24 - Back-up Power (BP) Connector

+

24

-

+24V DC

-24V DC

Kinetix 350 Drive, Front View

Drive Cat. No.

Terminals

Recommended

Wire Size

mm

2

(AWG)

Strip Length

mm (in.)

Torque Value

N•m (lb•in)

2097-V3xPRx-LM

+24V DC

1.5 (16)

6 (0.25)

0.5 (4.5)

-24V DC

Advertising