Rockwell Automation 2097-Vxxx Kinetix 350 Single-axis EtherNet/IP Servo Drive User Manual User Manual
Page 47

Rockwell Automation Publication 2097-UM002C-EN-P - December 2013
47
Kinetix 350 Drive Connector Data Chapter 3
This is the motor thermostat interface schematic. Although the thermostat signal
is shown for all feedback types, some motors do not support this feature because
it is not part of the feedback device.
Figure 20 - Motor Thermostat Interface
Table 17 - Motor Thermostat State Specifications
Table 18 - Stegmann Hiperface Specifications
Figure 21 - Stegmann Hiperface Interface, SIN and COS Signals
+5V
1 kΩ
6.81 kΩ
0.01 μF
TS
+5V
Kinetix 350 Drive
State
Resistance at TS
(1)
(1) Resistance is measured between TS (MF pin 11) and ECOM (MF pin 6)
No Fault
500 Ω
Fault
10 kΩ
Attribute
Value
Protocol
Hiperface
Memory support
Not programmed, or programmed with Allen-Bradley motor data
Hiperface data communication
RS485, 9600 bps, 8 data bits, no parity
Sine/Cosine interpolation
2048 counts/sine period
Input frequency (AM/BM)
250 kHz, max
Input voltage (AM/BM)
0.6...1.2V, p-p, measured at the drive inputs
Line loss detection (AM/BM)
Average (sin
2
+ cos
2
) > constant
56 pF
SIN+ or
COS+
SIN- or
COS-
+
1 kΩ
-
to AqB Counter
1 kΩ
10 kΩ
10 kΩ
1 kΩ
1 kΩ
1 kΩ
56 pF
56 pF
26.7 kΩ
47 pF
to A/D Converter
56 pF
+5V
1 kΩ
+
-
1 kΩ
Kinetix 350 Drive