Ethernet communication specifications, 24v dc back-up power specifications – Rockwell Automation 2097-Vxxx Kinetix 350 Single-axis EtherNet/IP Servo Drive User Manual User Manual
Page 45

Rockwell Automation Publication 2097-UM002C-EN-P - December 2013
45
Kinetix 350 Drive Connector Data Chapter 3
Ethernet Communication Specifications
An RJ45 100 Mbit Ethernet connector (port 1) is provided on the Kinetix 350
drive. It is fully compliant to the EtherNet/IP standard. Restrict the location of
all Ethernet cabling to clean zones with minimal electromagnetic interference.
24V DC Back-up Power Specifications
The Kinetix 350 drive can use an external power supply to power the logic and
communication circuits. If an independent 24V (@ 1 A) power supply is
connected to the BP connector, the logic and communication circuits remain
active during a mains input power loss.
Attribute
Value
Communication
100BASE-TX, full duplex
Auto MDI/MDIX crossover detection/correction
Yes
Cabling
Rockwell Automation CAT5E shielded, 100 m
(328 ft), max
Attribute
Value
Input voltage
20…26V DC
Current
500 mA
Inrush, max
30 A