Chapter 5 Configure and Start Up the Kinetix 350 Drive System

Configure the Kinetix 350 Drive

Follow these steps to configure the Kinetix 350 drive.

1. Right-click the Logix5000 EtherNet/IP controller you just created and

choose New Module.

The Select Module dialog box appears.

2. Clear the Module Type Category Filter and check the Motion category.
3. Select your 2097-V3xPRx-LM drive as appropriate for your actual

hardware configuration and click Create.

IMPORTANT

To configure Kinetix 350 drive (catalog numbers 2097-V3xPRx-LM) you must be
using RSLogix 5000 software, version 20 or later, or Logix Designer Application.