2.

If no sender file matches the sender being used, the individual points that map resistance points to oil
pressure may be modified by setting numeric values in the table, or dragging the points of the graph
to the desired characteristic. Information on sender characteristics should be obtained from the
sender manufacturer.

3.

Select Positive or Negative sender slope as required for the desired sender graph.

4.

Click Save Oil Data to save the data in the current settings file.

5.

If you want to save newly entered sender data as a sender library file, click Create Oil Settings File
and enter a file name and location to save the file.

6.

Click the Send Settings button in BESTCOMSPlus to send the sender settings to the DGC-2020ES.

Figure 9. Settings Explorer, Programmable Senders, Oil Pressure Screen

Coolant Temperature

Figure 10 illustrates the Coolant Temperature screen found in the BESTCOMSPlus Settings Explorer
under the Programmable Senders category. To program the fuel level sender, perform the following
procedure:

1.

The coolant temperature sender can be configured by selecting one of the sender types that come as
a part of the BESTCOMSPlus sender library. Click on Load Cool Settings File and select the
appropriate sender.

2.

If no sender file matches the sender being used, the individual points that map resistance points to
coolant temperature may be modified by setting numeric values in the table, or by dragging the points
of the graph to the desired characteristic. Information on sender characteristics should be obtained
from the sender manufacturer.

3.

Select Positive or Negative sender slope as required for the desired sender graph.

DGC-2020ES