Chapter 60 MRPP Configuration

60-7

60.4 MRPP Troubleshooting

The normal operation of MRPP protocol depends on normal configuration of each switch on MRPP ring,

otherwise it is very possible to form ring and broadcast storm:

Configuring MRPP ring, you’d better disconnected the ring, and wait for each switch configuration,

then open the ring.

When the MRPP ring of enabled switch is disabled on MRPP ring, it ensures the ring of the MRPP

ring has been disconnected.

When there is broadcast storm on MRPP ring, it disconnects the ring firstly, and ensures if each

switch MRPP ring configuration on the ring is correct or not; if correct, restores the ring, and then

observes the ring is normal or not.

In normal configuration, it still forms ring broadcast storm or ring block, please open debug function

of primary node MRPP, and used show MRPP statistics command to observe states of primary

node and transfer node and statistics information is normal or not, and then sends results to our

Technology Service Center.