4 ulsm troubleshooting, Ulsm, Roubleshooting – PLANET XGS3-24040 User Manual

Page 553

Advertising
background image

Chapter 62 ULSM Configuration

62-4

SwitchB configuration task list:

Switch(Config)#ulsm group 1

Switch(Config)#interface ethernet 1/1

Switch(config-If-Ethernet1/1)#ulsm group 1 downlink

Switch(config-If-Ethernet1/1)#exit

Switch(Config)#interface ethernet 1/3

Switch(config-If-Ethernet1/3)#ulsm group 1 uplink

Switch(config-If-Ethernet1/3)#exit

SwitchC configuration task list:

Switch(Config)#ulsm group 1

Switch(Config)#interface ethernet 1/2

Switch(config-If-Ethernet1/2)#ulsm group 1 downlink

Switch(config-If-Ethernet1/2)#exit

Switch(Config)#interface ethernet 1/4

Switch(config-If-Ethernet1/4)#ulsm group 1 uplink

Switch(config-If-Ethernet1/4)#exit

62.4 ULSM Troubleshooting

With the normal configuration, if the downlink port does not responds the down event of the uplink

port, please enable the debug function of ULSM, copy the debug information of 3 minutes and the

configuration information, and send them to our technical service center.

Advertising