2 format and severity of the log information – PLANET XGS3-24040 User Manual

Page 568

Advertising
background image

Chapter 66 Monitor and Debug

66-4

Note: the NVRAM log buffer may not exist on some switches, which only have the SDRAM log

buffer zone.

It is recommended to use the system log server. By configuring the log host on the switch, the log

can be sent to the log server for future examination.

66.7.1.2 Format and Severity of the Log Information

The log information format is compatible with the BSD syslog protocol, so we can record and analyze the log

by the systlog (system log protect session) on the UNIX/LINUX, as well as syslog similar applications on PC.

The log information is classified into eight classes by severity or emergency procedure. One level per value

and the higher the emergency level the log information has, the smaller its value will be. For example, the

level of critical is 2, and warning is 4, debugging is leveled at 7, so the critical is higher than warnings which no

doubt is high than debugging. The rule applied in filtering the log information by severity level is that: only the

log information with level equal to or higher than the threshold will be outputted. So when the severity

threshold is set to debugging, all information will be outputted and if set to critical, only critical, alerts and

emergencies will be outputted.

Follow table summarized the log information severity level and brief description. Note: these severity levels

are in accordance with the standard UNIX/LINUX syslog.

Table 1-1 Severity of the log information

Severity

Value

Description

emergencies

0

System is unusable

alerts

1

Action must be taken immediately

critical

2

Critical conditions

errors

3

Error conditions

warnings

4

Warning conditions

notifications

5

Normal but significant condition

informational

6

Informational messages

debugging

7

Debug-level messages

Right now the switch can generate information of following four levels

Restart the switch, mission abnormal, hot plug on the CHASSIS switch chips are classified critical

Up/down interface, topology change, aggregate port state change of the interface are notifications

warnings

Outputted information from the CLI command is classified informational

Information from the debugging of CLI command is classified debugging

Log information can be automatically sent to corresponding channels with regard to respective severity levels.