Table d-1 standard configuration item defaults – GE Industrial Solutions Pulsar Plus Controller User Manual

Page 179

Advertising
background image

Pulsar Plus Controller Family

Issue 7 December 2011

179

Table D-1 Standard Configuration Item Defaults

Factory Default

Factory 24V

Rectifier

Default

Factory 48V

Rectifier

Default

Category

Description

Range

Factory

Factory 24V

Factory 48V

obj,attr

Auxiliary Alarms

Auxiliary Alarm 1 Description

<=32 chars

"Air Conditioner Fail"

AUX1,DES

Auxiliary Alarm 1 Front Panel Desc

<=24 chars

"Air Conditioner Fail"

AUX1,FDS

Auxiliary Alarm 2 Description

<=32 chars

"Door Open"

AUX2,DES

Auxiliary Alarm 2 Front Panel Desc

<=24 chars

"Door Open"

AUX2,FDS

Auxiliary Alarm 3 Description

<=32 chars

"High External Ambient"

AUX3,DES

Auxiliary Alarm 3 Front Panel Desc

<=24 chars

"High External Ambient"

AUX3,FDS

Auxiliary Alarm 4 Description

<=32 chars

"Low External Ambient"

AUX4,DES

Auxiliary Alarm 4 Front Panel Desc

<=24 chars

"Low External Ambient"

AUX4,FDS

Auxiliary Alarm 5 Description

<=32 chars

"Fan Fail"

AUX5,DES

Auxiliary Alarm 5 Front Panel Desc

<=24 chars

"Fan Fail"

AUX5,FDS

Auxiliary Alarm 6 Description

<=32 chars

"Hydrogen Present"

AUX6,DES

Auxiliary Alarm 6 Front Panel Desc

<=24 chars

"Hydrogen Present"

AUX6,FDS

Ringers

Ringer Output Voltage Set-Point

65-100 VAC

100

RP1,VSP

Ringer Output Frequency

15-50Hz

20

RP1,FRQ

Ringer DC Output Offset Feature

1=Enabled/

0=Disabled

1

RP1,OFE

Ringer Redundancy Loss Feature

1=Enabled/

0=Disabled

1

RP1,RME

Alarm Test

Alarm Test Enable

1=Enabled

0=Disabled

1

AT1,LTE

Duration of Each Relay Closure

5 to 300 sec

30

AT1,DUR

PCR Relay Test Enable

1=Enabled

0=Disabled

1

AT1,PCR

PMJ Relay Test Enable

1=Enabled

0=Disabled

1

AT1,PMJ

PMN Relay Test Enable

1=Enabled

0=Disabled

1

AT1,PMN

R1 Relay Test Enable

1=Enabled

0=Disabled

1

AT1,R1

R2 Relay Test Enable

1=Enabled0=Disabled

1

AT1,R2

R3 Relay Test Enable

1=Enabled

0=Disabled

1

AT1,R3

R4 Relay Test Enable

1=Enabled

0=Disabled

1

AT1,R4

R5 Relay Test Enable

1=Enabled

0=Disabled

1

AT1,R5

R6 Relay Test Enable

1=Enabled

0=Disabled

1

AT1,R6

R7 Relay Test Enable

1=Enabled

0=Disabled

1

AT1,R7

Buzzer Test Interval

5-300sec

10

AT1,BZI

Alarm Cut-Off

Critical Alarm Cut-off Enable

1=Enabled

0=Disabled

1

ACO1,CAE

Critical Alarm Cut-off Timeout

1 to 4 hours

1

ACO1,CTO

Major Alarm Cut-off Enable

1=Enabled

0=Disabled

1

ACO1,JAE

Major Alarm Cut-off Timeout

1 to 4 hours

1

ACO1,JTO

Minor Alarm Cut-off Enable

1=Enabled

0=Disabled

1

ACO1,NAE

Minor Alarm Cut-off Timeout

1 to 72 hours

8

ACO1,NTO

Local Buzzer Enable

1=Enabled

0=Disabled

1

ACO1,LBE

Communication

Ports

Communication Port Type

LOCAL or

MODEM

"LOCAL"

PS1,PTT

Local Port Write Access

1=Enabled

0=Disabled

1

LP1,WRE

Local RS-232 baud rate

2400/4800/ 9600/

Auto

"AUTO"

LP1,BDR